Home » Case Studies » BFM fitting Case Study: Plaster

BFM fitting Case Study: Plaster

BFM fitting Case Study: Plaster

A leading UK plaster manufacturer was having an issue with the flexible connectors on a vibrating sieve lasting only a week at a time
before tearing, causing major dust leakage and requiring significant maintenance downtime. Plaster is very fine and is difficult to
contain, but since installing BFM® fittings, there are no dust leaks and the connectors have already lasted more than 50 times longer
than the previous jubilee-clip fastened connectors.

Before BFM fittings

The existing flexible sleeves connecting a vibratory feeder were made from corrugated rubber were wearing and fastened with traditional jubilee clips.

They leaked constantly, and had to be replaced weekly due to the jubilee clip causing chafing and tearing due to the
continuous gyratory movement.

This poor fit and constant tearing of the flexible sleeve caused excessive dust leakage and considerable maintenance downtime to
replace and clean up. There were also health & safety compliance issues as the existing sleeves had no ATEX certification.

Plaster BFM fitting Before & After

Implementing BFM fittings

BFM® Seeflex 040AS (anti-static) sleeves have been fitted to both the inlet and outlet to the vibratory feeder with great results. To date, the BFM® connectors have lasted over 50 times longer than the previous jubilee-clip fastened sleeve, saving a huge amount of expense in both replacement connectors and downtime.

The extremely fine plaster powder has been contained in a sealed system, so there are no longer issues with dust leaks and associated
clean-up. The BFM® Seeflex 040AS connectors are also ATEX compliant, so combined with a cleaner, dust-free environment, reducing a number of health & safety concerns.

“Plaster is very fine and gets everywhere. It is difficult to contain, particularly when your connecting sleeve has holes in it! BFM® has
been brilliant. The connector seals inside the spigot so it can’t chafe on the sharp edges and there are no jubilee clips to tear the
fabric. It lasts for longer and best of all it doesn’t leak any dust.” Works Engineer

Case Study provided courtesy of BFM® Distributor ProSpare, United Kingdom.

 

If you think BFM® fittings would be appropriate in your facility, fill out the form below and we’ll get back to you within one (1) business day to discuss your installation opportunities!

 

Want to share this Case Study with a co-worker? Download the PDF here.

 



x

BFM Fittings

We've moved

PSI's BFM fittings now have their own website. Click “Learn more” below to be redirected to to the new site.

Go Back Learn More

We've moved